2 V4_06  06/04/2000
 The following version numbers apply to this version of Mn_Fit:

 Mn_Fit      4.06/14
 Mn_Util     1.11/14
 TYPSCN      1.02/16
 CGR_MINUIT  1.00/15
 DBASE       1.05/06
 L3_DSP      1.02/16
 ZEUS_DSP    1.00/05

 This section lists the changes that have been made since
 Mn_Fit version 4.05/34.

 This release has been tested with the 99 and 2000 releases of the
 CERN libraries. Versions earlier than 98 are known to have date/time
 problems. It will only work with versions 94b or later.

 +++ Known Bugs or Problems:
 ___________________________


 `DRAW' commands with the mouse on only work in CM.

 You cannnot give a range of array elements to use in a `CUT'
 command. This only works in the variables to be projected. If you
 need to do something fancy like this you have to use a COMIS function
 for the cut.

 You can only access a variable in a CWN using the `DEPOSIT/EXAMINE'
 commands.


 +++ New Features:
 _________________


 Cernlib version 99 is now the default. Version 2000 is recommended.

 This version of Mn_Fit should be Y2K compatible.

 Font -1004 is default for all sites and platforms. This means that
 the text stays as it was on the screen, but uses Helvetica Poscript
 fonts when you print the pictures - see HELP Text for more
 information.

 The axis labels are now aligned with the left (bottom), centre or
 right (top) of the plot as well as being appropriately adjusted. This
 makes it easy to make them the same as default PAW position.

 Symbols 50-79 added which put a small line (symbol size) at the end
 of an error bar.

 The ZEUS display for FTD has been improved significantly and new
 options have been added.


 +++ New Commands:
 _________________


 SET TKTCL      Turns on/off the TK/TCL interface.
 HELP Y2K       Explains how years from 2000 onwards are implemented.


 +++ Modified Commands:
 ______________________


 DATABASE DB_SNAP     Can now handle years from 2000 onwards.
 DATABASE DB_HISTORY  Can now handle years from 2000 onwards.
 SET X|Y|Z LABEL      Alignment option implemented fully.
 SET SYMBOL           New symbols added to put cross-bars on errors.
 SET PAR FTD          More options added.


 +++ Improvements and Bug Fixes:
 _______________________________


 Cernlib version 99 is now the default. 2000 is recommended.

 This version of Mn_Fit should be Y2K compatible.

 The axis labels are now aligned with the left (bottom), centre or
 right (top) of the plot as well as being appropriately adjusted. This
 makes it easy to make them the same as default PAW position.

 Symbols 50-79 added which put a small line (symbol size) at the end
 of an error bar.

 Trimming of the last number on the y-axis was done whatever the window
 spacing.

 `CUT LIST' crashed if a cut filename was longer than 55 characters.

 Added TOPDRAW  smoothing routines (SMCTRL) to the list of routines
 known by COMIS.

 Select options structured better. New experiments DESYAFS and CERNAFS
 introduced. @ removed from experiment name. BONNCIP added instead of
 CIP being an extra option. L3 and ZEUS displays can be explicitly
 selected instead of being implicit in ZEUS and L3. The flags L3DSP
 and ZEUSDSP in the Mn_Fit code have been renamed to L3DSP_SRC and
 ZEUSDSP_SRC, as L3DSP and ZEUSDSP are used in the scripts.

 Several bug fixes to allow Mn_Fit to be compiled and run with bounds
 checking and debug.

 L3 database interface did not work with 99, 2000 versions of the CERN
 libraries. Call to MZDIV now added, I/O is now with CIO and some
 other minor fixes.

 A bug in the making of the test histograms meant that the test script
 for `DAT_STORE' also had to be corrected.